Single Limb Manometer Introduction:

A single-limb manometer is a liquid column manometer, which measures low to modest pressure or vacuum in gases. It differs from the conventional U-tube manometer in that it has only one vertical tube, which is linked with a reservoir or well at the bottom. The displacement is usually measured relative to a zero point, and the liquid level in the vertical limb rises or falls with the application of either positive or negative pressure in the vertical limb.

This design is easier to read and install, particularly in applications that require limited space or where a direct, vertical measurement is desired. Single-limb manometers are usually applied in the laboratory, HVAC systems, gas flow measurements, and low-pressure calibration purposes. The precision of the device is influenced by the nature of the manometric fluid (such as mercury or water), scale calibration, and environmental conditions such as temperature and vibration.

They are easy to read and interpret and are well suited in applications where simple but accurate monitoring of pressure is needed.

Mechanism of Single Limb Manometer:

A single-limb manometer works on the hydrostatic pressure balance in a column of liquid. It comprises a vertical transparent tube (the limb) that is linked to a reservoir or well at the bottom that is partially filled with a manometric liquid such as mercury, water, or oil.

At zero pressure, the liquid levels in the limb and the reservoir are at a balanced reference point. When pressure is applied via the pressure inlet that is connected to the reservoir:

In case of positive pressure, the liquid in the reservoir is forced down by the applied pressure, and the liquid in the vertical tube rises.

When the vacuum or negative pressure is applied, the pressure within the reservoir is less than atmospheric pressure, and thus the liquid within the vertical tube is pulled down.

This mechanism is simple, and thus the single-limb manometer can be used to measure low pressure and is best where the measurement is controlled, such as in the laboratory and test setups.

Uses of Single-Limb Manometer:

The single-limb manometer is very common in the measurement of low to moderate gas pressure or vacuum level with high precision. It is applicable in different laboratories and industrial uses since it is easy to build and its scale of reading is clear, particularly where direct reading of pressure is crucial. Major applications are

Laboratory Experiments:

Applied in physics and engineering laboratories to illustrate principles of pressure, calibrate instruments, and perform experiments with gas laws and pressure differences.

HVAC and Airflow Monitoring:

Assists in the determination of air duct pressures, fan static pressure, or pressure drop across filters of heating, ventilation, and air conditioning systems.

Gas Flow and Regulation Systems:

Applied to systems containing gas pipelines, regulators, and combustion equipment to check and regulate low gas pressures.

Instrument calibration and testing:

It serves as a calibration standard to calibrate pressure gauges, sensors, and transducers because of its great accuracy and ease of use.

Monitoring of industrial processes:

Applied in industrial low-pressure uses such as boiler drafts, furnace pressure, and cleanroom pressure measurements.

The single-limb manometer is particularly favored due to its clarity, ease of use, and precision in situations where visual indication of pressure changes is considered useful.

Single-limb manometer classes:

Single-limb manometers are available in a variety of versions, each of which is adapted to different needs in the measurement of pressure. Although all of them are based on the same principle, a vertical tube connected to a fluid reservoir (well), they may be different in their arrangement and application. The principal ones are

Single-limb open-well manometer:

The most widespread.

One of the ends is connected to the pressure source and the other to the atmosphere.

Pressure is measured using the difference in height in the single limb.

Can be used with low to moderate pressures.

Single-Limb Manometer Sealed Well:

The well is capped and usually pre-vacated.

Applied to measure absolute pressure because of the absence of atmospheric effect.

More sensitive and precise, however, applied to certain controlled applications.

Inclined Single Limb Manometer:

The single tube is not vertical but inclined, making the scale longer.

Gives more precision in low-pressure reading, owing to the finer resolution.

Perfect to sense small pressure variations, like in airflow channels or in the laboratory.

Type: Enlarged Reservoir (with Wide Well):

The cross-sectional area of the well or reservoir is much greater than that of the vertical limb.

Makes sure that the liquid in the well does not change its level much, thus all the pressure movement can be seen in the single vertical tube.

Handy to give readings more accurately and slight errors of fluid displacement.

Depending on the pressure range, accuracy required, fluid used, and environment it is used in, each type of single-limb manometer is selected.

Positive features of the single-limb manometer:

Simple Construction:

Simple to use, read, and maintain.

There are no moving parts to increase the likelihood of mechanical failure.

High Accuracy:

Suitable to make accurate low-pressure measurements.

Provides direct pressure indication on displacement of liquid.

Clear Visibility:

A single vertical limb gives easy and fast reading.

Readability is enhanced by a graded scale.

Cost-Effective:

Cheap as opposed to electronic or digital pressure measurement devices.

Demerits of Single-Limb Manometer:

Capable of Low Pressure Range:

Inappropriate in high-pressure applications, since it would involve high liquid columns.

Oriented to Sensitive:

Should be mounted vertically to get the right readings.

Temperature and Vibration Sensitive:

Reading errors may be introduced by liquid expansion or vibration of the system.

Not Portable:

Glass tubes and open fluid columns: It is fragile and not suitable in rough situations.

No Real-Time Monitoring or Distant Output:

No electronic interface, no digital readout, no automation, no data logging.

Single Limb Manometer disposal must be done with care, particularly when it is contaminated with dangerous chemicals such as mercury. First, disconnect the manometer from any system and properly drain the manometric fluid. When the fluid is mercury, it should be considered hazardous waste and should be disposed of by a licensed hazardous waste disposal facility. The glassware parts, when clean and free of mercury, may be recycled with other laboratory glassware; when contaminated, they must be capped and labeled to be disposed of as hazardous materials. With manometers that contain non-toxic fluids (water or liquids based on alcohol), drain and dispose of the liquid based on local environmental laws, and recycle the clear glass and metal components where possible. When disposing of anything, always observe the manufacturer guidelines and local waste disposal regulations to dispose of it in a safe, legal, and environmentally friendly manner.

¼”, 3/8”, 1/2”, NOZZLE
Wall Mounting, Stand Mounting
ASTM A216 GR. WCB(CS), SS 316, SS 304, PTFE, BOROSILICATE GLASS, ALUMINIUM, ACRYLIC, M.S, P.P, RUBBER, CAF, and other as per customer requirement.

FAQs

The difference in pressure between two limbs of a tube is measured in a U-tube manometer, but in a single-limb manometer, one leg of the tube is open to a large-surfaced reservoir so that the pressure can be read directly on the vertical limb, frequently using a simplified scale.

The most common fluids are mercury in high-pressure applications and water or alcohol in low-pressure applications. The selection of fluid is based on the pressure range, fluid density, and compatibility with the gas being measured.

It is applied in laboratories, heating, ventilating, and air-conditioning systems, in gas pipes, and in calibration systems to accurately measure small pressure differences. It is better where there is a need to have visual confirmation and be simple.

The single-limb model enables readings to be made more easily and more quickly since one need simply read the level of the fluid in a single vertical tube instead of measuring the difference between two limbs, as with a U-tube manometer.

No, it is most appropriate where there are low to moderate pressure measurements. It is not very well suited to high-pressure applications owing to constraints on tube height and fluid retention.

Although mercury is accurate and stable, it is also a toxic substance and an environmental hazard. Disposal, breakage, and handling are safety issues and regulated.

Yes, when well calibrated, it is very accurate and stable, particularly in measuring the static pressure. Nevertheless, it might not be appropriate in the case of dynamic or variable pressure systems.

Single-limb manometers are usually delicate since they are made of glass and may be cumbersome to carry around or to use in harsh conditions. They also need a stable, level installation to give correct readings.

The manometer must be fixed in a vertical plane only to give proper results. When mounting, use a leveling tool to eliminate angular errors that may influence the measurement of fluid heights.

Select the fluid depending on the range of pressure and the type of gas.

  • High-pressure differentials should be made of mercury.
  • Low-pressure applications should use water or light oil.

Make sure that the fluid is compatible with the process gas and can fit in the environmental conditions (e.g., temperature, corrosion resistance).

Yes, the reservoir or well must be stationary and at the bottom of the vertical arm and the fluid level should have a zero reference point before utilization. The tilt or imbalance will cause erroneous readings.

Flexible airtight tubing should be used and should be compatible with the gas being measured. Ensure that the connections are joined properly to prevent leakages or loss of pressure that will corrupt the results.

Yes, do not bring the manometer near vibrating machines, heat, or drafts. A sudden change of temperature or movement can change the level of the fluid, and this can affect the accuracy of the readings.

The manometer must be safely removed and disconnected from the system prior to disposal, and manometric fluid drained out. Clean and decontaminate the unit, with all process material left over.

When the manometer is not made of harmful materials, then the glass tube can be recycled along with the rest of the laboratory glassware. However, once it is poisoned (e.g., mercury), it is to be disposed of as a hazardous waste.

Mercury is a poisonous element and equipment that contains it should be considered as hazardous waste. The mercury must be handled with a lot of care and collected in tightly sealed containers and taken to a licensed hazardous waste disposal site.

In the case of non-toxic manometric fluid (i.e. water or an alcohol-based solution), the fluid can be drained in a safe manner as per the local environment regulations. The parts of the manometer can be recycled or sent to non-hazardous waste after cleaning.

Yes, the disposal should be in accordance with local and national environmental laws and particularly where the manometer holds dangerous materials such as mercury. Waste management authorities or the instructions provided by the manufacturer should always be consulted to make sure that it is handled legally and environmentally.